ADB
Construction
- Long casing with motor inside the duct
- Standard diameters from 500 until 1250mm
- Steel welded casing with two identical flanges
- Standard hot dip galvanized after construction
- Direct driven with motor completely outside the air flow
- Cast aluminum or cast iron motor IEC B3 3x400V 50Hz
- Impeller with cast aluminum center boss and plastics blades
- Airflow selectable, motor <> impeller
- Impeller balanced following the norm ISO 1940-1 quality G6.3
Alternative
- Non-standard dimensions
- Stainless steel construction
- Special coating
- Specific motor
- Aluminum blades
- Construction following Atex norms type Gas II 2G 3G | Dust II 2D 3D
Application
Fan mostly used for special applications, such as in a high temperature or high humidity environment.